Home
loading content

DeviceBus for ODVA DeviceNet

12 items

3082k
Approx LBS/MFT305
AWG Size16
Color Code ChartRed, Black/Blue, White
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp75C
NEC TypeCMG/CL2/PLTC
Requires Quote 
3082kp
Approx LBS/MFT305
AWG Size16
Color Code ChartRed, Black/Blue, White
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp75C
NEC TypeCMG/ITC/PLTC/TC
Requires Quote 
3082a
Approx LBS/MFT138
Color Code ChartRed, Black/Blue, White
Composite Construction(1) Power Pair 15 AWG 19/28 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 18 AWG 19/30 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp75C
NEC TypeCMG/PLTC-ER
Requires Quote per FT 
3082f
Approx LBS/MFT140
Color Code ChartRed, Black/Blue, White
Composite Construction(1) Power Pair 15 AWG 65/33 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 18 AWG 65/36 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp75C
NEC TypeCMG/PLTC-ER
Requires Quote per FT 
3083a
Approx LBS/MFT137
Color Code ChartRed, Black/Blue, White
Composite Construction(1) Power Pair 15 AWG 19/28 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 18 AWG 19/30 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialChlorinated Polyethylene (CPE)
Max. Temp75C
NEC TypeCMG/PLTC
Requires Quote per FT 
3084a
Approx LBS/MFT47
Color Code ChartRed, Black/Blue, White
Composite Construction(1) Power Pair 22 AWG 19/34 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 24 AWG 19/36 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp75C
Min. Temp-20C
Requires Quote per FT 
3084f
Approx LBS/MFT47
Color Code ChartRed, Black/Blue, White
Composite Construction(1) Power Pair 22 AWG 154/44 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 24 AWG 105/44 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialPolyvinylchloride (PVC)
Max. Temp75C
NEC TypeCL2/CMG
Requires Quote per FT 
3085a
Approx LBS/MFT47
Color Code ChartRed, Black/Blue, White
Composite Construction(1) Power Pair 22 AWG 19/34 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 24 AWG 19/36 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket
Cond. MaterialTinned Copper
Dielectric MaterialPolyvinylchloride (PVC)/Foam Polyethylene (FPE)
Jacket MaterialChlorinated Polyethylene (CPE)
Max. Temp75C
Min. Temp-30C
Requires Quote per FT