600V Tray Cable Pairs and Triads

72 items

AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness0.084
Requires Quote 
Approx LBS/MFT83
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT141
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT262
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT383
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT507
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT763
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote 
Approx LBS/MFT1016
AWG Size18
Color Code ChartE1
Cond. MaterialBare Copper
Conductor Stranding7/26
CSA TypeFT4
Dielectric MaterialPolyvinylchloride (PVC)/Nylon
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote 

Belden 600V UL Tray Cable (Pairs and Triads) Specifications

Belden Tray Cable Ratings and Approvals:

  • UL Subject 1277 TC
  • UL 1685 (UL 1581) Vertical Tray Flame Test (comparable to IEEE 383-1974)
  • NEC Type TC
  • PVC/Nylon/PVC Parts: NEC Type NPLF (Non-Power-Limited Fire-Protective Signaling Circuits)
  • PVC/Nylon/PVC and XLPE/PVC Parts: IEEE 1202/IEEE 383-2003/FT 4 (70,000 BTU) Flame Test
  • Voltage Rating: 600V

Belden Tray Cable Construction:

  • Conductor: Soft Annealed Bare or Tinned Copper
  • Insulation: Polyvinylchloride (PVC) with Nylon Overcoat or Cross-linked Polyethylene (XLPE)
  • Jacket: 90°C Polyvinylchloride (PVC)
  • Shield: Individually and Overall Beldfoil, Overall Beldfoil, or Unshielded