Home
loading content

Unshielded Multi-Conductor Type TC-ER

25 items

181800-18
Approx LBS/MFT118
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Ground AWG Size14
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
181805-18
Approx LBS/MFT160
AWG Size12
Cond. MaterialTinned Copper
Conductor Stranding7/.0305
Ground AWG Size12
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
181810-18
Approx LBS/MFT240
AWG Size10
Cond. MaterialTinned Copper
Conductor Stranding7/.0385
Ground AWG Size10
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
130500-18
Approx LBS/MFT223
AWG Size8
Cond. MaterialTinned Copper
Conductor Stranding7/.0486
Ground AWG Size10
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
169335-18
Approx LBS/MFT421
AWG Size8
Cond. MaterialTinned Copper
Conductor Stranding7/.0486
Ground AWG Size10
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
169340-18
Approx LBS/MFT600
AWG Size6
Cond. MaterialTinned Copper
Conductor Stranding7/.0612
Ground AWG Size8
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
183105-18
Approx LBS/MFT481
AWG Size6
Cond. MaterialTinned Copper
Conductor Stranding7/.0612
Ground AWG Size8
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote 
169345-18
Approx LBS/MFT882
AWG Size4
Cond. MaterialTinned Copper
Conductor Stranding7/.0772
Ground AWG Size8
Ground Wire MaterialUninsulated Tinned Copper
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialCross-Linked Chlorinated Polyethylene (XL-CPE)
Requires Quote