Home
loading content

XLPE/Arctic-Grade PVC with Overall Shielded Pairs/Triads

11 items

Approx LBS/MFT600
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding7/.0152
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.080
Max. Temp90C
Requires Quote 
Approx LBS/MFT761
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding7/.0152
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.080
Max. Temp90C
Requires Quote 
Approx LBS/MFT1603
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding7/.0152
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.080
Max. Temp90C
Requires Quote 
Approx LBS/MFT46
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding7/.0152
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.045
Max. Temp90C
Requires Quote 
Approx LBS/MFT121
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding7/.0192
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.045
Max. Temp90C
Requires Quote 
Approx LBS/MFT486
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding7/.0192
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.080
Max. Temp90C
Requires Quote 
Approx LBS/MFT616
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding7/.0192
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.080
Max. Temp90C
Requires Quote 
Approx LBS/MFT734
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding7/.0192
Insul. MaterialCross-Linked Polyethylene (XLPE)
Jacket MaterialPolyvinylchloride (PVC)
Jacket Thickness.080
Max. Temp90C
Requires Quote 

XLPE/Arctic-Grade PVC Instrumentation Cable with Overall Shielded Pairs/Triads Specifications

XLPE/Arctic-Grade PVC Instrumentation Cable Construction:

  • Conductor: 18 AWG and 16 AWC tinned, annealed copper per ASTM B33, Class B stranding per ASTM B8
  • Insulation: Flame retardant Cross-Linked Polyethylene (XLPE)
  • Color-coded per ICEA Method 1: Pairs: Black and White; Triads: Black, White, and Red
  • Shield: Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire
  • Jacket: Flame retardant and sunlight-resistant Arctic-grade Polyvinylchloride (PVC)
  • Options:
    • Bare copper conductor
    • Class C Stranding
    • E-2 Color Code
    • CSA Rated TC for 14 AWG and larger
    • Other constructions available upon request

XLPE/Arctic-Grade PVC Instrumentation Cable Ratings and Approvals:

  • Voltage Rating: 600V
  • Max. Temperature: 90°C wet or dry
  • UL 1277 Type TC
  • UL 1581
  • CSA C22.2 No. 239 Type CIC
  • UL 1581 VW-1
  • UL 1277 Flame Test
  • CSA FT-4
  • IEEE 383
  • EPA 40 CFR, Part 261 for leachable lead content per TCLP
  • OSHA acceptable

XLPE/Arctic-Grade PVC Instrumentation Cable Features:

  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Sunlight and weather resistant
  • Meets CSA cold impact test at -40°C
  • Meets ICEA and CSA cold bend test at -65°C

XLPE/Arctic-Grade PVC Instrumentation Cable Applications:

  • Typical applications include industrial lighting, control, and signaling circuits
  • Primary installations cable trays, raceways, or outdoor applications when supported by a messenger wire
  • In wet or dry locations