Home
loading content

Classic 100 CY Cable

The Lapp Olflex Classic 100 CY Cable is a control cable suitable for use in control systems, assembly lines, control panels, data processing equipment, and European-influenced machinery. This cable features PVC insulation and a pressure extruded PVC jacket for improved flexibility. It also features a braided tinned copper shield that provides 85 percent coverage. This cable is also CE Approved and RoHS Compliant.

32 items

Approx LBS/MFT50
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.2760
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Approx LBS/MFT67
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.3110
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Approx LBS/MFT75
AWG Size20
Cond. MaterialBare Copper
Copper LBS/MFT44
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Nom. O.D. (in)0.3310
Requires Quote 
Approx LBS/MFT66
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT38
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.3110
Requires Quote 
Approx LBS/MFT75
AWG Size18
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Nom. O.D. (in)0.323
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Approx LBS/MFT87
AWG Size18
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.3430
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Approx LBS/MFT103
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT60
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Nom. O.D. (in)60
Requires Quote 
Approx LBS/MFT89
AWG Size16
Cond. MaterialBare Copper
Copper LBS/MFT44
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.3900
Requires Quote 

Lapp Classic 100 CY Control Cable Specifications

Classic 100 CY Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 Fine Wire) - *2c cable does not include a ground wire
  • Insulation: PVC
  • Color Code: VDE 0293-308
  • Shielding: Gray PVC inner jacket; tinned copper braid (85% coverage)
  • Jacket: Gray PVC

Classic 100 CY Cable Ratings:

  • Temperature Range:
    • For flexible use: -5°C to +70°C
    • For stationary use: -40°C to +80°C
  • Nominal Voltage:
    • 16 AWG and Smaller: 300/500V
    • 14 AWG and Larger: 450/750 V
  • Test Voltage: 4000V
  • Minimum Bend Radius (shielded): 6 x cable diameter

Classic 100 CY Cable Approvals and Benefits:

  • Based on VDE specifications
  • CE & RoHS compliant
  • Meets European color code for power
  • Pressure extruded jacket for improved flexibility
  • Inner jacket and tinned copper braid offer EMI protection