The Lapp Olflex Classic 100 CY Cable is a control cable suitable for use in control systems, assembly lines, control panels, data processing equipment, and European-influenced machinery. This cable features PVC insulation and a pressure extruded PVC jacket for improved flexibility. It also features a braided tinned copper shield that provides 85 percent coverage. This cable is also CE Approved and RoHS Compliant.

32 items

0035001
Approx LBS/MFT50
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.2760
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Quote Only
00350033
Approx LBS/MFT67
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.3110
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Quote Only
00352013
Approx LBS/MFT75
AWG Size20
Cond. MaterialBare Copper
Copper LBS/MFT44
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Nom. O.D. (in)0.3310
Requires Quote 
Quote Only
0035220
Approx LBS/MFT66
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT38
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.3110
Requires Quote 
Quote Only
0035221
Approx LBS/MFT75
AWG Size18
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Nom. O.D. (in)0.323
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Quote Only
00352223
Approx LBS/MFT87
AWG Size18
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.3430
ShieldInner Jacket and Overall Braid Shield
Requires Quote 
Quote Only
00352233
Approx LBS/MFT103
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT60
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Nom. O.D. (in)60
Requires Quote 
Quote Only
0035000
Approx LBS/MFT89
AWG Size16
Cond. MaterialBare Copper
Copper LBS/MFT44
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.3900
Requires Quote 
Quote Only

Lapp Classic 100 CY Control Cable Specifications

Classic 100 CY Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 Fine Wire) - *2c cable does not include a ground wire
  • Insulation: PVC
  • Color Code: VDE 0293-308
  • Shielding: Gray PVC inner jacket; tinned copper braid (85% coverage)
  • Jacket: Gray PVC

Classic 100 CY Cable Ratings:

  • Temperature Range:
    • For flexible use: -5°C to +70°C
    • For stationary use: -40°C to +80°C
  • Nominal Voltage:
    • 16 AWG and Smaller: 300/500V
    • 14 AWG and Larger: 450/750 V
  • Test Voltage: 4000V
  • Minimum Bend Radius (shielded): 6 x cable diameter

Classic 100 CY Cable Approvals and Benefits:

  • Based on VDE specifications
  • CE & RoHS compliant
  • Meets European color code for power
  • Pressure extruded jacket for improved flexibility
  • Inner jacket and tinned copper braid offer EMI protection