Home
loading content

590 CP Cable

The Lapp 590 CP Cable is a control cable suitable for use in portable hand tools, utility and forestry equipment, cold temperature applications, and applications where the cable may be cut or damaged by sharp objects. This cable's TPE insulation provides superior low-temperature flexibility and its rugged PUR jacket resists cuts, nicks, and abrasion. This cable features an overall foil tape with drain wire and tinned copper braid shield for EMI and RFI protection. It may be used in wet, dry, indoor, and outdoor applications. 

16 items

Approx LBS/MFT73
AWG Size18
Cond. MaterialTinned Copper
Copper LBS/MFT34
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Requires Quote 
Approx LBS/MFT84
AWG Size18
Cond. MaterialTinned Copper
Copper LBS/MFT41
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Requires Quote 
Approx LBS/MFT99
AWG Size18
Cond. MaterialBare Copper
CSA TypeWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Min. Temp-50C
Requires Quote 
Approx LBS/MFT73
AWG Size16
Cond. MaterialTinned Copper
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Min. Temp-50C
Requires Quote 
Approx LBS/MFT86.00
AWG Size16
Cond. MaterialTinned Copper
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Min. Temp-50C
Requires Quote per FT 
Approx LBS/MFT99
AWG Size16
Cond. MaterialTinned Copper
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Min. Temp-50C
Requires Quote 
Approx LBS/MFT118.00
AWG Size16
Cond. MaterialTinned Copper
Copper LBS/MFT67
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Requires Quote per FT 
Approx LBS/MFT0.00
AWG Size14
Cond. MaterialTinned Copper
Copper LBS/MFT71
CSA TypeAWM I/II A/B
Insul. MaterialThermoplastic Elastomer (TPE)
Jacket MaterialPolyurethane (PUR)
Max. Temp80C
Requires Quote 

Lapp 590 CP Control Cable Specifications

590 CP Cable Construction:

  • Conductor: Finely stranded tinned copper (Class 5 fine wire) - *2 conductor cable does not include ground
  • Insulation: TPE
  • Shielding: Overall foil tape with drain wire; Overall tinned copper braid (85% coverage)
  • Jacket: Yellow polyurethane

590 CP Cable Ratings and Approvals:

  • Temperature Range (for flexible use): -50°C to +80°C
  • Minimum Bend Radius (shielded): 8 x cable diameter
  • Nominal Voltage: 600V
  • Testing Voltage: 2000V
  • UL: AWM 20234
  • Attributes:
    • UL Oil Res I/II
    • Sunlight resistant
    • NFPA 79 2012
  • CSA: AWM I/II A/B FT1
  • CE and RoHS compliant