EcoSafe CO IV

10 items

ecosafe 8 l4
Approx LBS/MFT86.00
AWG Size8
Cond. MaterialTinned Copper
Conductor Stranding41
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall60
Max. Resistance @ 20C OHMS/MFT0.679 (DC)
Nom. I.D. (in)0.28
Requires Quote 
ecosafe 6 l4
Approx LBS/MFT132.00
AWG Size6
Cond. MaterialTinned Copper
Conductor Stranding65
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall60
Max. Resistance @ 20C OHMS/MFT0.436 (DC)
Nom. I.D. (in)0.32
Requires Quote 
ecosafe 4 l4
Approx LBS/MFT185.00
AWG Size4
Cond. MaterialTinned Copper
Conductor Stranding105
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall60
Max. Resistance @ 20C OHMS/MFT0.274 (DC)
Nom. I.D. (in)0.39
Requires Quote 
ecosafe 2 l4
Approx LBS/MFT279.00
AWG Size2
Cond. MaterialTinned Copper
Conductor Stranding168
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall60
Max. Resistance @ 20C OHMS/MFT0.172 (DC)
Nom. I.D. (in)0.43
Requires Quote 
ecosafe 1/0 l4
Approx LBS/MFT435.00
AWG Size1/0
Cond. MaterialTinned Copper
Conductor Stranding266
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall80
Max. Resistance @ 20C OHMS/MFT0.109 (DC)
Nom. I.D. (in)0.56
Requires Quote 
ecosafe 2/0 l4
Approx LBS/MFT525.00
AWG Size2/0
Cond. MaterialTinned Copper
Conductor Stranding342
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall80
Max. Resistance @ 20C OHMS/MFT0.087 (DC)
Nom. I.D. (in)0.62
Requires Quote 
ecosafe 4/0 l4
Approx LBS/MFT819.00
AWG Size4/0
Cond. MaterialTinned Copper
Conductor Stranding532
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall80
Max. Resistance @ 20C OHMS/MFT0.055 (DC)
Nom. I.D. (in)0.75
Requires Quote 
ecosafe 350 l4
Approx LBS/MFT1319.00
AWG Size350 kcmil/MCM
Cond. MaterialTinned Copper
Conductor Stranding888
Insul. Materiallow smoke, zero halogen, lead-free, heat and moisture resistant, silicone free composite with natural cotton braid
Insulation Min. Avg. Wall95
Max. Resistance @ 20C OHMS/MFT0.033 (DC)
Nom. I.D. (in)0.96
Requires Quote