UL 3321 wire has excellent mechanical and electrical properties. This wire is known for its unparalleled thermal stability, toughness, and abrasion resistance. It is compatible with all magnet wire and most varnishes. Its irradiated cross-linked insulation will not melt or flow at soldering temperatures. UL 3321 wire is often used in appliances, transformers, motors, ballasts, lighting, electrical heating, and cooking equipment. This wire also possesses outstanding resistance to abrasion, deformation, cut-through and chemical attack.

9 items

Approx LBS/MFT6.00
AWG Size22
Cond. MaterialTinned Copper
Conductor Stranding7/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands7
Requires Quote per FT 
Approx LBS/MFT7.00
AWG Size20
Cond. MaterialTinned Copper
Conductor Stranding10/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands10
Requires Quote per FT 
Approx LBS/MFT10.00
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding16/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands16
Starting at 0.10 per FT 
Approx LBS/MFT13.00
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding26/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands26
Starting at 0.24 per FT 
Approx LBS/MFT19.00
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding41/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands41
Starting at 0.25 per FT 
Approx LBS/MFT27.00
AWG Size12
Cond. MaterialTinned Copper
Conductor Stranding65/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands65
Starting at 0.36 per FT 
Approx LBS/MFT42.00
AWG Size10
Cond. MaterialTinned Copper
Conductor Stranding105/30
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands105
Starting at 0.66 
Approx LBS/MFT66.00
AWG Size8
Cond. MaterialTinned Copper
Conductor Stranding133/29
CSA TypeAWM/CL1503
Insul. MaterialCross-Linked Polyethylene (XLPE)
Max. Temp150C
No. of Strands133
Requires Quote per FT 

UL 3321 Wire Specifications

UL 3321 Wire Construction:

  • Conductor: Fully annealed tinned copper, flexible stranding
  • Insulation: Chemically cross-linked Polyethylene (XLPE)

UL 3321 Wire Ratings and Approvals:

  • Temperature Rating: 150°C
  • Voltage Rating: 600 volts
  • Meets UL 3321/UL 3505 and CL 1503/AWM
  • RoHS Compliant