31 items
- 
                                        
                                        0.00 /
- Approx LBS/MFT: 52
 - AWG Size: 16
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        0.00 /
- Approx LBS/MFT: 66
 - AWG Size: 16
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        0.00 /
- Approx LBS/MFT: 74
 - AWG Size: 14
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        0.00 /
- Approx LBS/MFT: 118
 - AWG Size: 14
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        0.00 /
- Approx LBS/MFT: 471
 - AWG Size: 14
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        FREP/CPE 14-3C0.00 / 1000 FT
- Approx LBS/MFT: 95.00
 - AWG Size: 14
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        FREP/CPE 14-5C0.00 / 1000 FT
- Approx LBS/MFT: 142
 - AWG Size: 14
 - Cond. Material: Tinned Copper
 
 - 
                                        
                                        FREP/CPE 14-7C0.00 / 1000 FT
- Approx LBS/MFT: 176.00
 - AWG Size: 14
 - Cond. Material: Tinned Copper
 
 
FR-EPR/CPE Shielded Multi-Conductor Control Cable (Type TC-ER) Specifications
FR-EPR/CPE Shielded Control Cable (Type TC-ER) Construction:
- Conductor: 16 AWG through 10 AWG fully annealed stranded tinned copper per ASTM B33; Class B stranding per ASTM B8
 - Insulation: Flame Retardant Ethylene Propylene Rubber (FR-EPR) Type II
	
- Color-coded per ICEA Method 1; Table E-2 (Does not include white or green)
 
 - Shield: Overall Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
 - Jacket: Flame Retardant Thermoplastic Chlorinated Polyethylene (CPE) FR-EPR/CPE
 - Shielded Control Cable Options:
	
- 2kV version
 - Bare copper conductor
 - Class C stranding
 - E-1 Color Code
 - Unshielded
 - Flame Retardant Cross-Linked Polyethylene (FR-XLPE) insulation
 - Thermoplastic Low-Smoke, Zero-Halogen (LSZH) jacket
 - Other constructions available upon request
 
 
FR-EPR/CPE Shielded Control Cable (Type TC-ER) Ratings and Approvals:
- Voltage Rating: 600V
 - Max. Temperature: 90°C, wet or dry
 - UL 44 Type XHHW-2
 - UL 1277 Type TC-ER (three or more conductors)
 - UL 1581
 - ICEA S-73-532
 - UL 1581 VW-1
 - UL 1277 Flame Test
 - IEEE 383
 - IEEE 1202
 - CSA FT4
 - ICEA T-29-520
 
FR-EPR/CPE Shielded Control Cable (Type TC-ER) Features:
- Ripcord applied to all cables with jacket thickness of 60 mils or less
 - Excellent physical, thermal, and electrical properties
 - Sunlight and weather resistant
 - Excellent moisture resistance
 - Outstanding resistance to crush, compression cuts, and heat deformation
 - Low coefficient of friction for easy pulling
 - Excellent flame-resistance; burns to ash; does not exhibit thermoplastic drip
 - Excellent low-temperature cold bend characteristics
 - Meets cold bend test at -40°C
 - Meets the crush and impact requirements of Type MC cable (three conductors or more)
 
FR-EPR/CPE Shielded Control Cable (Type TC-ER) Applications:
- In free air, raceways, or direct burial
 - In wet or dry locations
 - Permitted for Exposed Run 'ER' use in accordance with NEC for 2 AWG and larger
 - Permitted for use in Class I Division 2 industrial hazardous locations per NEC