Home
loading content

Shielded Multi-Conductor Type TC-ER

31 items

140235-18
Approx LBS/MFT52
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding7/.0192
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote 
140245-18
Approx LBS/MFT66
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding7/.0192
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote 
140490-18
Approx LBS/MFT74
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote 
152650-18
Approx LBS/MFT118
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote 
152680-18
Approx LBS/MFT471
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.060
Max. Temp90C
Requires Quote 
frep/cpe 14-3c
Approx LBS/MFT95.00
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote per FT 
frep/cpe 14-5c
Approx LBS/MFT142
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote per FT 
frep/cpe 14-7c
Approx LBS/MFT176.00
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding7/.0242
Insul. MaterialFlame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
Jacket MaterialFlame-Retardant Chlorinated Polyethylene (FR-CPE)
Jacket Thickness0.045
Max. Temp90C
Requires Quote per FT 

FR-EPR/CPE Shielded Multi-Conductor Control Cable (Type TC-ER) Specifications

FR-EPR/CPE Shielded Control Cable (Type TC-ER) Construction:

  • Conductor: 16 AWG through 10 AWG fully annealed stranded tinned copper per ASTM B33; Class B stranding per ASTM B8
  • Insulation: Flame Retardant Ethylene Propylene Rubber (FR-EPR) Type II
    • Color-coded per ICEA Method 1; Table E-2 (Does not include white or green)
  • Shield: Overall Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
  • Jacket: Flame Retardant Thermoplastic Chlorinated Polyethylene (CPE) FR-EPR/CPE
  • Shielded Control Cable Options:
    • 2kV version
    • Bare copper conductor
    • Class C stranding
    • E-1 Color Code
    • Unshielded
    • Flame Retardant Cross-Linked Polyethylene (FR-XLPE) insulation
    • Thermoplastic Low-Smoke, Zero-Halogen (LSZH) jacket
    • Other constructions available upon request

FR-EPR/CPE Shielded Control Cable (Type TC-ER) Ratings and Approvals:

  • Voltage Rating: 600V
  • Max. Temperature: 90°C, wet or dry
  • UL 44 Type XHHW-2
  • UL 1277 Type TC-ER (three or more conductors)
  • UL 1581
  • ICEA S-73-532
  • UL 1581 VW-1
  • UL 1277 Flame Test
  • IEEE 383
  • IEEE 1202
  • CSA FT4
  • ICEA T-29-520

FR-EPR/CPE Shielded Control Cable (Type TC-ER) Features:

  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Excellent physical, thermal, and electrical properties
  • Sunlight and weather resistant
  • Excellent moisture resistance
  • Outstanding resistance to crush, compression cuts, and heat deformation
  • Low coefficient of friction for easy pulling
  • Excellent flame-resistance; burns to ash; does not exhibit thermoplastic drip
  • Excellent low-temperature cold bend characteristics
  • Meets cold bend test at -40°C
  • Meets the crush and impact requirements of Type MC cable (three conductors or more)

FR-EPR/CPE Shielded Control Cable (Type TC-ER) Applications:

  • In free air, raceways, or direct burial
  • In wet or dry locations
  • Permitted for Exposed Run 'ER' use in accordance with NEC for 2 AWG and larger
  • Permitted for use in Class I Division 2 industrial hazardous locations per NEC