Home
loading content

Classic 100 Cable

The Lapp Olflex Classic 100 Cable is a control cable suitable for use in control systems, assembly lines, control panels, data processing equipment, and European-influenced machinery. This cable features PVC insulation and a pressure extruded PVC jacket for improved flexibility. It is also CE Approved and RoHS Compliant.

42 items

00100004
Approx LBS/MFT24
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.1890
Voltage300/500V
Requires Quote 
olflex 00100014
Approx LBS/MFT28
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Nom. O.D. (in)0.2010
Voltage300/500
Requires Quote 
olflex 00100024
Approx LBS/MFT36
AWG Size20
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.2240
Voltage300/500V
Requires Quote 
olflex 00100414
Approx LBS/MFT36
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT13
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.2240
Requires Quote 
00100424
Approx LBS/MFT44
AWG Size18
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Nom. O.D. (in)0.2360
Voltage300/500V
Requires Quote 
00100434
Approx LBS/MFT53
AWG Size18
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Nom. O.D. (in)0.2560
Voltage300/500
Requires Quote 
00100444
Approx LBS/MFT63
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT32
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Nom. O.D. (in)0.28
Requires Quote 
00100634
Approx LBS/MFT46
AWG Size16
Cond. MaterialBare Copper
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.2
Nom. O.D. (in)0.2480
Voltage300/500
Requires Quote 

Lapp Classic 100 Control Cable Specifications

Classic 100 Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 Fine Wire) - *2c cable does not include a ground wire
  • Insulation: PVC
  • Color Code: VDE 0293-308
  • Jacket: Gray PVC

Classic 100 Cable Ratings:

  • Temperature Range:
    • For flexible use: -5°C to +70°C
    • For stationary use: -40°C to +80°C
  • Nominal Voltage:
    • 16 AWG and Smaller: 300/500V
    • 14 AWG and Larger: 450/750 V
  • Test Voltage: 4000V
  • Minimum Bend Radius (for installation): 4 x cable diameter

Classic 100 Cable Approvals and Benefits:

  • Based on VDE specifications
  • CE & RoHS compliant
  • Meets European color code for power
  • Pressure extruded jacket for improved flexibility