Fortis Cable

The Lapp Fortis Cable is suitable for use in wind energy applications, machine tools, forestry equipment, oil and petrochem equipment, cold temperature storage, and packaging facilities. This cable meets torsion requirements for wind turbine applications and is TC-ER rated. The copper core is dual-rated for North American and European standards: 18 AWG (1mm2) to 6 AWG (16 mm2). 

40 items

331803
Approx LBS/MFT57
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT20
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331804
Approx LBS/MFT66
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT26
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331805
Approx LBS/MFT77
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT33
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331807
Approx LBS/MFT99
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT46
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331809
Approx LBS/MFT112
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT59
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331812
Approx LBS/MFT172
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT79
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331818
Approx LBS/MFT245
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT118
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 
331825
Approx LBS/MFT322
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT164
CSA TypeAWM I/II A/B FT4
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialElastomeric Polymer
Max. TempTemperature Range: UL/CSA TC: -25C to 90C; For flexible use: -40C to 105C; For stationary use: -55C to 105C
Requires Quote 

Lapp Fortis Tray Cable Specifications

Fortis Cable Construction:

  • Conductors: Finely stranded bare copper
  • Insulation: Specially blended PVC/Nylon
  • Color Code: Black with white numbers, plus green/yellow ground
  • Jacket: Specially formulated oil-resistant elastomeric black polymer

Fortis Cable Ratings and Approvals:

  • Temperature Range:
    • UL/CSA TC: -25°C to 90°C
    • For flexible use: -40°C to 105°C
    • For stationary use: -55°C to 105°C
  • Nominal Voltage:
    • UL/CSA TC: 600V
    • UL WTTC: 1000V
  • Minimum Bend Radius for Installation: 4 x cable diameter
  • UL Approval:
    • TC-ER per UL 1277
    • MTW per UL 1063 
    • WTTC per UL 2277
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight Resistant
    • NFPA 79 2012
  • CSA Approval:
    • c(UL) CIC/TC FT4
    • CSA AWM I/II A/B FT4
  • NEC Approval
    • Class 1 Division 2 per NEC Article 501
  • CE Approved
  • RoHS Compliant
  • Torsion Rated for Wind Market (± 90°/m) & (± 150°/m)
  • Arctic-grade jacket passes UL -40°C cold impact test