add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

Belden DeviceBus for ODVA DeviceNet

Part Number AWG SizeNo. of Cond.No. of PairsComposite ConstructionNom. DCR of Cond.Nom. O.D. (in)Nom. Imp.Nom. Cap. (pF/ft)Approx LBS/MFT
7897A 4 (2) 15 AWG 19/28 Tinned Copper Conductors with PVC/Nylon Insulation, (2) 18 AWG 19/30 Tinned Copper Conductors with FEP Insulation, Individually and Overall Shielded with Overall Jacket 3.6O/M'/6.9O/M' 0.4600 120 12 135
7896A 4 (2) 16 AWG 19/29 Tinned Copper Conductors with PVC/Nylon Insulation, (2) 18 AWG 19/30 Tinned Copper Conductors with F-R Polypropylene Insulation, Individually and Overall Shielded with Overall Jacket 4.9O/M'/6.9O/M' 0.5250 120 14.7 168
7900A 4 (2) 16 AWG 19/29 Tinned Copper Conductors with PVC/Nylon Insulation, (2) 18 AWG 19/30 Tinned Copper Conductors with F-R Polypropylene Insulation, Overall Jacket 4.9O/M'/6.9O/M' 0.4300 120 14.7 105
3082A 2 (1) Power Pair 15 AWG 19/28 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 18 AWG 19/30 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 3.6O/M'/6.9O/M' 0.4800 120 12.0 138
3082F 2 (1) Power Pair 15 AWG 65/33 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 18 AWG 65/36 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 3.6O/M'/6.9O/M' 0.4800 120 12.0 140
3083A 2 (1) Power Pair 15 AWG 19/28 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 18 AWG 19/30 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 3.6O/M'/6.9O/M' 0.4750 120 12.0 137
3084A 2 (1) Power Pair 22 AWG 19/34 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 24 AWG 19/36 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 17.5O/M'/28.0O/M' 0.2800 120 12.0 47
3084F 2 (1) Power Pair 22 AWG 154/44 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 24 AWG 105/44 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 17.5O/M'/28.0O/M' 0.2750 120 12.0 47
3085A 2 (1) Power Pair 22 AWG 19/34 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 24 AWG 19/36 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 17.5O/M'/28.0O/M' 0.2800 120 12.0 47
7895A 2 (1) Power Pair 18 AWG 19/30 Tinned Copper Conductors with PVC Insulation, (1) Data Pair 20 AWG 19/32 Tinned Copper Conductors with FPE Insulation, Individually Foil Shielded, Overall Braid Shield, Overall Jacket 6.9O/M'/10.9O/M' 0.3780 120 12.0 305
3082K 16 4 4.9O/M' .760x.210 120 14.7 305
3082KP 16 4 4.9O/M' .760x.210 305
DeviceBus for ODVA DeviceNet
Belden Industrial Cable
Data Cable

ODVA DeviceNet Cable Ratings and Approvals:

  • Temperature Rating: 75°C
  • Voltage Rating: 300V or 600V
  • UL AWM 20201 (600V)
  • C(UL) AWM I/II A or C(UL) AWM I/II A/B (select parts only)

DeviceNet Cable, DeviceBus Construction:

  • Conductor: Stranded Tinned Copper
  • Insulation:
    • Power Cable: PVC/Nylon or PVC
    • Data Cable: Fluorinated Ethylene-Propylene (FEP), Flame-Retardant Polypropylene, or Foam Polyethylene (FPE)
  • Jacket: CPE, Sunlight/Oil-resistant PVC, or Sunlight-resistant PVC
  • Shielding: Individually Foil Shielded and Overall Tinned Copper Braid or Unshielded
  • Color Code:
    • Power Pair: Red and Black
    • Data Pair: Blue and White