add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

Belden Plenum Cable with Overall Foil/Braid Shield

Part Number AWG SizeNo. of Cond.Conductor StrandingNom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)Approx LBS/MFTNom. Cap. (C-C)Nom. Cap. (C-SC)
83503 24 3 7/32 0.006 0.014 0.135 16 20 36
83504 24 4 7/32 0.006 0.014 0.144 20 20 36
83506 24 6 7/32 0.006 0.014 0.165 26 20 36
83509 24 9 7/32 0.006 0.014 0.188 34 20 36
83512 24 12 7/32 0.006 0.014 0.207 42 20 36
83515 24 15 7/32 0.006 0.014 0.227 50 20 36
83552 22 2 7/30 0.007 0.014 0.141 16 35 63
83553 22 3 7/30 0.007 0.014 0.148 20 23 40
83554 22 4 7/30 0.007 0.014 0.159 25 23 40
83556 22 6 7/30 0.007 0.014 0.183 33 23 40
83559 22 9 7/30 0.007 0.014 0.209 46 23 40
83562 22 12 7/30 0.007 0.015 0.234 57 23 40
83569 22 19 7/30 0.007 0.015 0.269 81 23 40
83602 20 2 7/28 0.006 0.014 0.157 22 44 80
83604 20 4 7/28 0.006 0.014 0.178 32 26 51
83606 20 6 7/28 0.006 0.014 0.207 43 26 51
83609 20 9 7/28 0.006 0.014 0.238 60 26 51
83612 20 12 7/28 0.006 0.014 0.265 63 26 51
83652 18 2 19/30 0.007 0.014 0.171 26 33 60
83653 18 3 19/30 0.007 0.014 0.180 43 33 60
83654 18 4 19/30 0.007 0.014 0.195 42 33 60
83656 18 6 19/30 0.007 0.014 0.228 58 33 60
83659 18 9 19/30 0.007 0.015 0.265 81 33 60
83662 18 12 19/30 0.007 0.015 0.296 102 33 60
83702 16 2 19/29 0.007 0.014 0.196 37 35 63
83703 16 3 19/29 0.007 0.014 0.206 46 35 63
83704 16 4 19/29 0.007 0.014 0.223 58 35 63
83706 16 6 19/29 0.007 0.014 0.265 82 35 63
83709 16 9 19/29 0.007 0.014 0.307 115 35 63
83712 16 12 19/29 0.007 0.014 0.344 148 35 63
83715 16 15 19/29 0.007 0.014 0.407 181 35 63
83719 16 19 19/29 0.007 0.014 0.403 218 35 63
Belden Plenum Cable with Overall Foil/Braid Shield
Audio, Control and Instrumentation Cable
Belden Multi-Conductor Cable

Belden Shielded Plenum Cable Ratings and Approvals:

  • Plenum-rated
  • UL NEC Type CMP
  • C(UL) CEC Type CMP
  • Flame Tests: UL NFPA 262, CSA FT6
  • Voltage Rating: 300 volts

Belden Shielded Plenum Cable Construction:

  • Conductor: Stranded Tinned Copper
  • Insulation: Fluorinated Ethylene Propylene (FEP)
  • Jacket: Red Fluorinated Ethylene Propylene (FEP)
  • Shield: Tinned Copper Braid (85% coverage) and Beldfoil® Aluminum/Polyester Foil (100% coverage)

Belden Shielded Plenum Cable Additional Info:

  • Belden plenum cables designed with an FEP jacket are recommended for use in outdoor and direct burial applications.