Home
loading content

Single Conductor

Our Single Conductor Underground power cable is suitable for direct burial applications, installations in ducts, and underground systems that operate at 600 volts or less. It is also suitable for non-code-complying temperature of 90°C in wet or dry locations in accordance with ICEA specifications. This cable is resistant to abrasion, sunlight, and impact. It is also offered with varying constructions.

11 items

carol 83008
Amps80
Approx LBS/MFT150
AWG Size8
Cond. MaterialBare Copper
Conductor Stranding133
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote 
carol 83006
Amps105
Approx LBS/MFT214
AWG Size6
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote 
carol 83004
Amps140
Approx LBS/MFT277
AWG Size4
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote 
carol 83001
Amps220
AWG Size1
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Min. Temp-40C
Requires Quote 
carol 83010
Amps260
Approx LBS/MFT563
AWG Size1/0
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote 
83020
Amps300
Approx LBS/MFT679
AWG Size2/0
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote per FT 
carol 83030
Amps350
Approx LBS/MFT809
AWG Size3/0
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote 
83040
Amps405
Approx LBS/MFT973
AWG Size4/0
Cond. MaterialBare Copper
Conductor Stranding259
Insul. MaterialEthylene Propylene Diene Monomer Rubber (EPDM)
Jacket MaterialSuper Vu-Tron
Max. Temp90C
Requires Quote per FT 

Aluminum Single Conductor Underground Power Cable Specifications

Single Conductor Underground Power Cable Construction:

  • Complete Cable:
    • Aluminum conductor insulated with Extruded Cross-Linked Polyethylene (XLPE)
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-105-692
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)

Single Conductor Underground Power Cable Ratings and Approvals:

  • Max. Temperature: 90°C wet or dry
  • Voltage Rating: 600V
  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Sizes 250 - 500 kcmil available with UL-allowed thin wall (0.080") insulation
  • CDC Combined Duct & Cable
  • Reeless Package
  • Alloy 8000 Aluminum Conductor
  • Type RHH/RHW-2 rating to UL 44
  • Type USE-2 per UL 44