Our Single Conductor Underground power cable is suitable for direct burial applications, installations in ducts, and underground systems that operate at 600 volts or less. It is also suitable for non-code-complying temperature of 90°C in wet or dry locations in accordance with ICEA specifications. This cable is resistant to abrasion, sunlight, and impact. It is also offered with varying constructions.

11 items

  • General Cable Carol Brand
    Carol 83008
    0.00 /
    • Amps: 80
    • Approx LBS/MFT: 150
    • AWG Size: 8
    Order
    Add to List
  • General Cable Carol Brand
    Carol 83006
    0.00 /
    • Amps: 105
    • Approx LBS/MFT: 214
    • AWG Size: 6
    Order
    Add to List
  • General Cable Carol Brand
    Carol 83004
    0.00 /
    • Amps: 140
    • Approx LBS/MFT: 277
    • AWG Size: 4
    Order
    Add to List
  • General Cable Carol Brand
    Carol 83001
    0.00 /
    • Amps: 220
    • AWG Size: 1
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    Carol 83010
    0.00 /
    • Amps: 260
    • Approx LBS/MFT: 563
    • AWG Size: 1/0
    Order
    Add to List
  • General Cable Carol Brand
    83020
    0.00 / 1000 FT
    • Amps: 300
    • Approx LBS/MFT: 679
    • AWG Size: 2/0
    Order
    Add to List
  • General Cable Carol Brand
    Carol 83030
    0.00 /
    • Amps: 350
    • Approx LBS/MFT: 809
    • AWG Size: 3/0
    Order
    Add to List
  • General Cable Carol Brand
    83040
    0.00 / 1000 FT
    • Amps: 405
    • Approx LBS/MFT: 973
    • AWG Size: 4/0
    Order
    Add to List

Aluminum Single Conductor Underground Power Cable Specifications

Single Conductor Underground Power Cable Construction:

  • Complete Cable:
    • Aluminum conductor insulated with Extruded Cross-Linked Polyethylene (XLPE)
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-105-692
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)

Single Conductor Underground Power Cable Ratings and Approvals:

  • Max. Temperature: 90°C wet or dry
  • Voltage Rating: 600V
  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Sizes 250 - 500 kcmil available with UL-allowed thin wall (0.080") insulation
  • CDC Combined Duct & Cable
  • Reeless Package
  • Alloy 8000 Aluminum Conductor
  • Type RHH/RHW-2 rating to UL 44
  • Type USE-2 per UL 44