Approx LBS/MFT10.75
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding19/29
Insul. MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyamide
Jacket Thickness0.003
Max O.D. (in)0.059
The M16878/18 hook-up wire is designed to be used in military harnessing, power supply lead wire, appliance wiring, and medical electronic devices. It is constructed with a stranded tinned copper conductor, PVC insulation, and an extruded polyamide jacket. The M16878/18 has a maximum temperature of 105°C and a voltage rating of 1000V.
M16878/18 Construction:
M16878/18 Ratings: