Home
loading content

300V Power Limited Tray Cable, PLTC/ITC Twisted Pairs and Triads

These Belden PLTC cables are ideal for instrumentation applications requiring sunlight, moisture, and vapor resistance. PVC/PVC cables 20 AWG or larger that have three or more conductors are suitable for use in direct burial applications. Unshielded cables are suitable for use in metallic conduit. Overall shielded cables are ideal for applications with signals transmitted at over 100 millivolts, but not in applications where sources of high voltage and current create a lot of noise and signal interference. Individually and overall shielded parts are a good choice for instrumentation applications requiring superior noise rejection.

164 items

Approx LBS/MFT43
AWG Size18
Color Code ChartE1
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT73
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
In Stock
Approx LBS/MFT109
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT135
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT190
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT270
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote per FT 
Approx LBS/MFT321
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote 
Approx LBS/MFT428
AWG Size18
Color Code ChartE2
Cond. MaterialTinned Copper
Conductor Stranding19/30
CSA TypeCMG FT4
Dielectric MaterialPolyvinylchloride (PVC)
Jacket MaterialPolyvinylchloride (PVC)
Requires Quote 

Belden UL Industrial Power Limited Tray Cable Specifications

UL PLTC Cable Ratings and Approvals:

  • NEC: PLTC, ITC, CMG
  • CEC: CMG FT4
  • IEEE 1202/383
  • ICEA T-29-520 Flame Test
  • UL Subject 13
  • UL Subject 2250
  • UL 1685 Vertical Tray Flame Test

UL PLTC Cable Construction:

  • Configuration: Twisted Pair Cable or Twisted Triad Cable
  • Conductor: Stranded Bare or Tinned Copper
  • Insulation: Polyvinylchloride (PVC)
  • Polyvinylchloride (PVC) (Black or Chrome)
  • Shield: varies, see part info