Home
loading content

CONTROL TM Cable

The Lapp Control TM Cable is suitable for use in machine tools, food and beverage equipment, and processing equipment. This cable features flexible copper stranding, a pressure-extruded jacket, and number-coded conductors for easy connection. It is also TC-ER approved, meaning it may be installed off the machine and into an overhead tray without conduit.

36 items

Approx LBS/MFT55
AWG Size18
Cond. MaterialBare Copper
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.3
Nom. O.D. (in)0.2910
Requires Quote 
Approx LBS/MFT64
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT26
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.4
Requires Quote 
Approx LBS/MFT75
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT33
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.5
Requires Quote 
Approx LBS/MFT97
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT46
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.7
Requires Quote 
Approx LBS/MFT108
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT59
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.9
Requires Quote 
Approx LBS/MFT165
AWG Size18
Cond. MaterialBare Copper
Copper LBS/MFT79
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.12
Requires Quote 
Approx LBS/MFT245
AWG Size18
Cond. MaterialBare Copper
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.18
Nom. O.D. (in)0.5790
Requires Quote 
Approx LBS/MFT262
AWG Size18
Cond. MaterialBare Copper
CSA TypeAWM I/II A/B
Insul. MaterialPolyvinylchloride (PVC)/Polyamide (Nylon)
Jacket MaterialPolyvinylchloride (PVC)
No. of Cond.19
Nom. O.D. (in)0.5790
Requires Quote 

Lapp Control TM Cable Specifications

Control TM Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 fine wire)
  • Insulation: Specially blended PVC/Nylon
  • Color Code: Black with white numbers, plus green/yellow ground
  • Jacket: Specially formulated gray PVC

Control TM Cable Ratings and Approvals:

  • Temperature Range:
    • UL/CSA TC: -25°C to +90°C
    • For stationary use: -40 to +105°C
    • For flexible use: -25°C to +90°C
  • Nominal Voltage:
    • UL/CSA TC: 600V
    • UL WTTC: 1000V
  • Test Voltage: 2000V
  • Minimum Bend Radius for Installation: 4 x cable diameter
  • UL:
    • TC-ER per UL 1277
    • MTW per UL 1063
    • WTTC per UL 2277
    • Bus Drop Cable (14 AWG & larger; 3c & 4c only)
    • AWM 2587 & 21098 (Oil)
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight resistant
    • Direct burial
    • NFPA 79 2012
  • NEC: Class 1, Division 2 per NEC Article 501
  • Canada:
    • c(UL) CIC/TC FT4
    • CSA AWM I/II A/B FT4
  • CE and RoHS Compliant
  • Additional:
    • Torsion rated for wind market (± 90°/m) & (± 150°/m)
    • Passes impact and crush test per UL 1277 (except 20 AWG)
    • Meets NFPA 79 2012 standards for wiring machinery (UL MTW)
    • UL TC-ER approved