Home
loading content

UL 5107

UL 5107

 UL 5107 meets all UL requirements for appliance lead wire and is also available with CSA certification. UL 5017 wire may be used for internal wiring of commercial, industrial, and household ovens. It is ideal for electric heaters and for equipment wiring in iron mills, steel mills, glass plants, and even cement kilns.  However, it can only be used where it is not exposed to repeated flexing and is protected from mechanical damage.

19 items

mg08-5107
Amps130
Approx LBS/MFT76.00
AWG Size8
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0111
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.015
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg6-5107
Amps175
Approx LBS/MFT115.00
AWG Size6
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0142
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.015
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg04-5107
Amps235
Approx LBS/MFT155.00
AWG Size4
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0177
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.015
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg2-5107
Amps315
Approx LBS/MFT0.00
AWG Size2
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0223
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg01-5107
Amps420
Approx LBS/MFT300.00
AWG Size1
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0177
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg1/0-5107
Amps490
Approx LBS/MFT380.00
AWG Size1/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0202
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg2/0-5107
Amps580
Approx LBS/MFT485.00
AWG Size2/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0229
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
mg3/0-5107
Amps675
Approx LBS/MFT600.00
AWG Size3/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0255
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 

UL 5107 High-Temperature Wire Specifications:

UL 5107 Wire Construction:

  • Jacket: Glass braid with PTFE high-temperature saturant (or silicone high-temperature saturant).
  • Insulation: Multiple layers of mica/glass composite tape.
  • Conductor: 27% nickel-coated copper.
  • Identification: Temperature ID as required by UL and CSA.

UL 5107 Additional Features:

  • Colors: Available in 10 standard colors.
  • Options: Nickel-coated iron conductor, solid nickel conductor, or nickel-plated copper conductor (250˚ C temperature rating with this option).
  • Rating: 450˚C, 600 Vac, and Horizontal flame tested.