UL 5359 wire is a mica reinforced hook-up wire with fiberglass braid insulation and a silicone finish. This wire has excellent thermal and flame resistance, good chemical resistance, and produces minimal smoke when exposed to flames. UL 5359 wire is ideal for electric heaters, equipment wiring in iron mills, steel mills, glass plants, and cement kilns. It is also often used for the internal wiring of domestic and commercial ovens as well as cooking appliances.

16 items

Approx LBS/MFT115.00
AWG Size6
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0142
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).015
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT175.00
AWG Size4
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0177
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).015
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT260.00
AWG Size2
Cond. MaterialNickel-Plated Copper
Conductor Stranding133/.0223
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT320.00
AWG Size1
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0177
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT400.00
AWG Size1/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0202
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT505.00
AWG Size2/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0229
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT620.00
AWG Size3/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0255
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT760.00
AWG Size4/0
Cond. MaterialNickel-Plated Copper
Conductor Stranding259/.0286
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).020
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 

UL 5359 High-Temperature Wire Specifications

UL 5359 Wire Construction:

  • Conductor: #22 AWG - #4/0 AWG flexible stranded 27% nickel-plated, annealed copper
  • Insulation: Glass reinforced phlogopite mica tapes
  • Jacket: A fiberglass braid jacket is applied over the insulation, then treated with a high-temperature finish
  • Color: Natural color is tan

UL 5359 Wire Ratings and Approvals:

  • Voltage Rating: 600 volts
  • Temperature Rating: 450°C
  • Non-UL: 538°C (1000°F)
  • UL Style 5359 rated
  • CSA AWM I A/B FT1
  • Passes 70,000 BTU/Hr and then 210,000 BTU/Hr industry-standard flame tests

UL 5359 Wire Features:

  • Excellent thermal and flame resistance
  • Good chemical resistance
  • Produces minimal smoke when exposed to flames