Home
loading content

M22759/34

Our M22759/34 wire is a highly durable Mil-Spec wire designed to be used in aircraft applications where weight, dimensional tolerance, and durability are a concern. This wire is constructed of tinned copper conductors, cross-linked ETFE insulation, an XL-ETFE jacket, and a treated aromatic polyamide braid shield. This wire is lightweight and has high resistance to chemicals and radiation. It also has a maximum temperature of +150°C and a voltage rating of 600V.

17 items

Approx LBS/MFT2.3, 2.30
AWG Size24
Cond. MaterialTinned Copper
Conductor Stranding19/36
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.047
Starting at 0.12 per FT 
Approx LBS/MFT3.2, 3.20
AWG Size22
Cond. MaterialTinned Copper
Conductor Stranding19/34
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.052
Starting at 0.15 per FT 
Approx LBS/MFT4.7, 4.70
AWG Size20
Cond. MaterialTinned Copper
Conductor Stranding19/32
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.06, 0.060
Starting at 0.20 per FT 
Approx LBS/MFT7.2, 7.20
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding19/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.073
Starting at 0.26 per FT 
Approx LBS/MFT9, 9.00
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding19/29
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.08, 0.080
Starting at 0.28 per FT 
Approx LBS/MFT0, 0.00
AWG Size14
Cond. MaterialTinned Copper
Conductor Stranding19/27
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.097
Starting at 0.45 per FT 
Approx LBS/MFT20.5, 20.50
AWG Size12
Cond. MaterialTinned Copper
Conductor Stranding37/28
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.114
Starting at 0.81 per FT 
Approx LBS/MFT32.4, 32.40
AWG Size10
Cond. MaterialTinned Copper
Conductor Stranding37/26
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Jacket MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
M27500 ComponentSD
Max O.D. (in)0.138
Starting at 1.25 per FT 

M22759/34 Mil-Spec Wire Specifications

M22759/34 Construction:

  • Conductor: Tinned Copper
  • Insulation: Fluoropolymer Cross-linked Modified ETFE Dual Insulation
  • Jacket: XL-ETFE
  • Braid: Treated aromatic polyamide for size 2

M22759/34 Ratings and Approvals:

  • Voltage Rating: 600 volts
  • Temperature Rating: 150°C
  • SAE: AS22759/34