Home
loading content

H07RN-F

The H07RN-F cable is suitable for use in dry, humid, or moist rooms, open-air, and workshops with an explosive atmosphere. It is suitable for use in a variety of applications subject to medium mechanical stresses, including industrial and agricultural workshop appliances, large boiling installations, heating plates, inspection lamps, and transportable motors or machines on building sites or in agricultural workings. This harmonized cable is ideal for use in electrical tools such as drills, circular saws, and domestic electric tools, and for the wiring of constructional components in lifting appliances, and machinery. HAR Cable is also suitable for a variety of fixed installations, such as on rough-cast in temporary buildings and huts for accommodation purposes.

53 items

Approx LBS/MFT0.00
AWG Size18
Cond. MaterialBare Copper
Conductor Stranding30/32
Insul. MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
No. of Strands30
Requires Quote 
Approx LBS/MFT81
AWG Size18
Cond. MaterialBare Copper
Conductor Stranding30/32
Insul. MaterialSynthetic Rubber
Jacket MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
Requires Quote per FT 
Approx LBS/MFT87.00
AWG Size18
Cond. MaterialBare Copper
Conductor Stranding30/32
Insul. MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
No. of Strands30
Requires Quote per FT 
Approx LBS/MFT114.00
AWG Size18
Cond. MaterialBare Copper
Conductor Stranding30/32
Insul. MaterialSynthetic Rubber
Jacket MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
Requires Quote per FT 
Approx LBS/MFT87.00
AWG Size16
Cond. MaterialBare Copper
Conductor Stranding27-29/30
Insul. MaterialSynthetic Rubber
Jacket MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
Requires Quote per FT 
Approx LBS/MFT101.00
AWG Size16
Cond. MaterialBare Copper
Conductor Stranding27-29/30
Insul. MaterialSynthetic Rubber
Jacket MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
Requires Quote per FT 
Approx LBS/MFT128
AWG Size16
Cond. MaterialBare Copper
Conductor Stranding27-29/30
Insul. MaterialSynthetic Rubber
Jacket MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
Requires Quote per FT 
Approx LBS/MFT155.00
AWG Size16
Cond. MaterialBare Copper
Conductor Stranding27-29/30
Insul. MaterialSynthetic Rubber
Jacket MaterialSynthetic Rubber
Max. Temp60C
Min. Temp-25C
Requires Quote 

H07RN-F Harmonized Cable Specifications

H07RN-F Construction:

  • Conductor: Stranded Bare Copper acc. to IEC 60228, EN 60228, VDE 0295, class 5
  • Insulation: Synthetic Rubber, EI4 acc. to DIN VDE 0282 part 1 + HD 22.1
  • Conductor Color Coding: acc. to HD 308 (VDE 0293-308)
  • Conductor Stranding: from 2 conductors stranded in layers
  • Jacket: Synthetic Rubber, EM2 acc. to DIN VDE 0282 part 1 + HD 22.1
  • Jacket Color: Black

H07RN-F Ratings and Approvals:

  • Temperature Range: -25°C to +60°C
  • Nominal Voltage: Uo/U 450/750 volts
  • Testing Voltage U: 2500 volts acc. to DIN VDE 0282 part 2 + HD 22.2
  • Min. Bending Radius: 15 x O.D.
  • VDE
  • HAR
  • CE
  • RoHS Compliant