TelcoFlex® IV Central Office Power Cable

Part Number AWG SizeConductor StrandingNom. I.D. (in)Nom. O.D. (in)Insulation Min. Avg. WallMax. Resistance @ 20°C OHMS/MFTApprox LBS/MFT
TELCO-8-L4 8 41/.0201 0.280 0.312 60 0.6790 93.00
TELCO-6-L4 6 65/.0201 0.315 0.350 60 0.4360 137.00
TELCO-4-L4 4 105/.0201 0.385 0.393 60 0.2740 199.00
TELCO-2-L4 2 168/.0201 0.430 0.470 60 0.1720 277.00
TELCO-1/0-L4 1/0 266/.0201 0.560 0.593 80 0.1090 460.00
TELCO-2/0-L4 2/0 342/.0201 0.620 0.648 80 0.0868 557.00
TELCO-4/0-L4 4/0 532/.0201 0.745 0.785 80 0.0546 868.00
TELCO-350-L4 350 888/.0201 0.960 1.000 95 0.0334 1345.00
TELCO-500-L4 500 1221/.0201 1.090 1.130 95 0.0234 1860.00
TELCO-750-L4 750 1850/.0201 1.320 1.360 110 0.0157 2738.00
Power Cable
TelcoFlex IV Central Office Cable

Class I Flexible Strand with Braid
Low smoke, Non-halogenated Insulation With Cotton Braid, Lead-Free and Silicone-Free, UL Listed RHH/LS FT4 and VVW-1, 90°C Dry, 60°C Wet, 600 Volts, UL Listed "For CT Use" (Sizes 1/0 AWG and Larger), CSA AWM / B 105°C, 600V, FT4

TelcoFlex IV Power Cable Description:

  • This cable incorporates low smoke zero halogen TelcoHyde insulation as well as an overall natural cotton braid soaked in a moisture resistant, fire retardant saturant. It also includes either a bunched or rope bunched stranded tinned copper conductor, covered with an opaque mylar tape to facilitate stripping.

Power Cable, TelcoFlex IV Ratings and Approvals:

  • Temperature Rating: 90°C Dry and 60°C Wet
  • Voltage Rating: 600V
  • UL: RHH/LS; Listed for CT Use (Sizes 1/0 AWG and Larger)
  • FT4-ST1 Flame Test
  • VW-1
  • ASTM B-33
  • CSA: AWM I B 105°C
  • IEC 60674 and 60332
  • RoHS and Reach Compliant

Power Cable, TelcoFlex® IV Construction:

  • Conductor: Class I (modified) bunched (8 and 6 AWG) and rope-bunched (4 AWG and larger) stranded tinned copper conductor
  • Insulation: Limited smoke, non-halogen TelcoHyde 5221, which features a limiting oxygen rating of 35%
  • Separator: 1 mil clear mylar tape is applied over the insulation for sizes 6 AWG and larger
  • Covering: Overall natural cotton braid. A section of completed cable has a limiting oxygen index of 35%.
  • Finish: Moisture resistant and flame retardant saturant and color finisher are applied to the braid.