Home
loading content

CMP Cable, FT6: Unshielded Twisted Pair Cable Plenum

11 items

6541ue
Approx LBS/MFT20
AWG Size22
Color Code ChartBlack/Red, Black/White
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote per FT 
6542ue
Approx LBS/MFT27
AWG Size22
Color Code ChartBlack/Red, Black/White, Black/Green
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote 
6543ue
Approx LBS/MFT34
AWG Size22
Color Code ChartBlack/Red, Black/White, Black/Green, Black/Blue
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote 
6545ue
Approx LBS/MFT47
AWG Size22
Color Code ChartBlack/Red, Black/White, Black/Green, Black/Blue, Black/Yellow, Black/Brown
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote 
6547ue
Approx LBS/MFT69
AWG Size22
Color Code ChartBlack/Red, Black/White, Black/Green, Black/Blue, Black/Yellow, Black/Brown, Black/Orange, Red/White, Red/Green
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.018
Requires Quote 
6561ue
Approx LBS/MFT19
AWG Size22
Color Code ChartBlack/Red, Black/White
Cond. MaterialBare Copper
Conductor Strandingsolid
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote 
6341ue
Approx LBS/MFT38
AWG Size18
Color Code ChartBlack/Red, Black/White
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote per FT 
6342ue
Approx LBS/MFT50
AWG Size18
Color Code ChartBlack/Red, Black/White, Black/Green
Cond. MaterialBare Copper
Conductor Stranding7
Insul. MaterialFlamarrest
Jacket MaterialFlamarrest
Jacket Thickness0.015
Requires Quote 

Belden Unshielded CMP Cable with Twisted Pairs (Plenum-Rated/NEC CMP, CEC CMP FT6) Specifications

CMP Cable Construction:

  • Conductors: Solid or Stranded Bare Copper
  • Insulation: Flamarrest
  • Configuration: Twisted into Pairs, Multiple Pairs Cabled Together
  • Jacket: Flamarrest
  • Jacket Color: Natural
  • RipCord

CMP Unshielded Twisted Pair Cable Ratings and Approvals:

  • NEC Rating: CMP
  • CEC Rating: CMP FT6
  • NEC Article: 800
  • Voltage Rating: 300V
  • Temperature Rating: 75°C

CMP Unshielded Twisted Pair Cable Applications:

  • Commercial Use
  • Plenum Use
  • Security Systems
  • Intercom and PA Systems
  • Sound and Audio Systems
  • Power-Limited Controls