Home
loading content

UL 5128

UL 5128

UL 5128 wire is manufactured from a reinforced mica tape insulation and a braided fiberglass jacket for enhanced abrasion resistance. UL 5128 wire meets all UL requirements for appliance lead wire and is also available with CSA certification. This wire may be used for applications in a high-temperature appliance, igniter cables for furnaces, thermocouple cables, electrical heaters, and other high-temperature cable applications. They are also used in military shipboard cables where low-smoke halogen-free cables are required.

7 items

Approx LBS/MFT6.00
AWG Size24
Cond. MaterialNickel-Plated Copper
Conductor Stranding7/.008
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote 
Approx LBS/MFT7.00
AWG Size22
Cond. MaterialNickel-Plated Copper
Conductor Stranding7/.0100
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT8.00
AWG Size20
Cond. MaterialNickel-Plated Copper
Conductor Stranding10/.0100
CSA TypeAWM I A/B FT1
Diameter (in)0.085
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote 
Approx LBS/MFT11.00
AWG Size18
Cond. MaterialNickel-Plated Copper
Conductor Stranding16/.0100
CSA TypeAWM I A/B FT1
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Max. Temp450C
Requires Quote per FT 
Approx LBS/MFT15.00, 64.30
AWG Size16
Cond. MaterialNickel-Plated Copper
Conductor Stranding26/.0100
CSA TypeAWM I A/B FT1
Diameter (in)0.105
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Approx LBS/MFT20.00
AWG Size14
Cond. MaterialNickel-Plated Copper
Conductor Stranding41/.0100
CSA TypeAWM I A/B FT1
Diameter (in)0.120
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Approx LBS/MFT29.00
AWG Size12
Cond. MaterialNickel-Plated Copper
Conductor Stranding65/.0100
CSA TypeAWM I A/B FT1
Diameter (in)0.140
Fiberglass Braid Thick. (in).007
Insul. MaterialMica/Glass Tapes/Overall Fiberglass Braid treated with High-Temp Saturant
Requires Quote 

UL 5128 High-Temperature Wire Specifications

UL 5128 Wire Construction:

  • Conductor: #24 AWG - #12 AWG flexible stranded 27% nickel-plated, annealed copper
  • Insulation: Glass reinforced phlogopite mica tapes
  • Jacket: A fiberglass braid jacket is applied over the insulation, then treated with a high-temperature finish
  • Color: Natural color is tan

UL 5128 Ratings and Approvals:

  • Voltage Rating: 300 volts
  • Temperature Rating: 450°C
  • Non-UL: 538°C (1000°F)
  • UL Style 5128 rated
  • CSA AWM I A/B FT1
  • Passes 70,000 BTU/Hr and then 210,000 BTU/Hr industry-standard flame tests

UL 5128 Wire Features:

  • Excellent thermal and flame resistance
  • Good chemical resistance
  • Produces minimal smoke when exposed to flames