UL 5196 Wire is one of the most popular appliance wires on the market today. This wire is widely used in extrusion machines, heater bands, and the wiring of appliances and fixtures. It's also found in internal wiring for commercial, industrial, and household ovens, as well as cooking and drying equipment. UL 5196 Wire may be used in both wet and dry applications. UL 5196 Wire meets the UL style requirement for UL 5196 for the high-temperature wires with a temperature rating of up to 250°C.

17 items

Amps9.5
Approx LBS/MFT4.75
AWG Size24
Cond. MaterialNickel-Plated Copper
Conductor Stranding7/.0080
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps12
Approx LBS/MFT8.00
AWG Size22
Cond. MaterialNickel-Plated Copper
Conductor Stranding7/.0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps16
Approx LBS/MFT10.00
AWG Size20
Cond. MaterialNickel-Plated Copper
Conductor Stranding10/.0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps23
Approx LBS/MFT13.00
AWG Size18
Cond. MaterialNickel-Plated Copper
Conductor Stranding16/.0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps29
Approx LBS/MFT17.00
AWG Size16
Cond. MaterialNickel-Plated Copper
Conductor Stranding26/.0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps40
Approx LBS/MFT23.00
AWG Size14
Cond. MaterialNickel-Plated Copper
Conductor Stranding41/0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps55
Approx LBS/MFT32.00
AWG Size12
Cond. MaterialNickel-Plated Copper
Conductor Stranding65/.0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 
Amps75
Approx LBS/MFT48.00
AWG Size10
Cond. MaterialNickel-Plated Copper
Conductor Stranding105/.0100
CSA TypeAWM I A/B
Fiberglass Braid Thick. (in)0.005
Insul. MaterialPTFE Tape/Fiberglass Serving/Fiberglass Braid treated with High-Temp Saturant
Requires Quote per FT 

UL 5196 Wire Specifications

UL 5196 Wire Construction:

  • Conductor: Single, stranded, and nickel-coated copper conductor.
  • Insulation: PTFE tapes covered by fiberglass covers UL 5196 Wire.
  • Jacket: Fiberglass(hi-temp) braid jacket overall.

UL 5196 Wire Ratings and Approvals:

  • Temperature Rating: 250°C
  • Voltage Rating: 600 volts
  • UL and CSA: UL 5196 / CSA AWC Class 1 Group A/B