The 55A0111 Tyco Raychem Spec 55 wire is a highly durable wire designed to be used as hook-up wire in applications where high temperatures, smoke emissions, and flammability are a concern. This wire is constructed of tinned copper conductors and XL-ETFE insulation. This wire also has a maximum temperature of +150°C and a voltage rating of 600V.

10 items

Approx LBS/MFT0.66
AWG Size30
Cond. MaterialTinned Copper
Conductor Stranding7/38
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote 
Approx LBS/MFT0.91
AWG Size28
Cond. MaterialTinned Copper
Conductor Stranding7/38
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT1.4
AWG Size26
Cond. MaterialTinned Copper
Conductor Stranding19/38
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT2.98
AWG Size24
Cond. MaterialTinned Copper
Conductor Stranding19/36
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT2.8
AWG Size22
Cond. MaterialTinned Copper
Conductor Stranding19/34
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT4.3
AWG Size20
Cond. MaterialTinned Copper
Conductor Stranding19/32
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp-65C
Mil-SpecM22759/32
Min. Temp150C
Requires Quote per FT 
Approx LBS/MFT6.5
AWG Size18
Cond. MaterialTinned Copper
Conductor Stranding19/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT8.3
AWG Size16
Cond. MaterialTinned Copper
Conductor Stranding19/29
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/32
Min. Temp-65C
Requires Quote per FT 

55A0111 Tyco Raychem Spec 55 (M22759/32) Specifications

55A0111 Spec 55 Construction:

  • Conductor: Tin Coated Copper
  • Insulation: Radiation-crosslinked, modified ETFE
  • Wall Thickness: 0.152 mm (0.006 in.)

55A0111 Raychem Spec 55 Ratings:

  • Min Temperature: - 65°C
  • Max Temperature: 150°C
  • Voltage: 600 Volts

55A0111 Raychem Spec 55 is classified as light weight wire and directly crosses with M22759/32 Mil-Spec Wire.