Home
loading content

55A0812 - M22759/43

The 55A0812 Tyco Raychem Spec 55 wire is a highly durable Mil-Spec wire designed to be used in aircraft and military applications where abrasion is a concern. This wire is constructed of silver-coated copper conductors, cross-linked ETFE insulation, a cross-linked ETFE jacket, and a treated aromatic polyamide braid shield. This wire also has a maximum temperature of +200°C and a voltage rating of 600V.

16 items

Approx LBS/MFT1.7
AWG Size26
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/38
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT2.3
AWG Size24
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/36
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT3.2
AWG Size22
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/34
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT4.7, 4.70
AWG Size20
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/32
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT7.2
AWG Size18
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT9
AWG Size16
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/29
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT13.8
AWG Size14
Cond. MaterialSilver-Coated Copper
Conductor Stranding19/27
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote 
Approx LBS/MFT20.5
AWG Size12
Cond. MaterialSilver-Coated Copper
Conductor Stranding37/28
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp200C
Mil-SpecM22759/43
Min. Temp-65C
Requires Quote per FT 

55A0812 Tyco Raychem Spec 55 (M22759/43) Specifications

55A0812 Spec 55 Construction:

  • Conductor: Silver-coated copper
  • Insulation: Radiation-crosslinked, modified ETFE
  • Wall Thickness: 0.254 mm (0.010 in.)
  • Wall Construction: Dual-Wall

55A0812 Spec 55 Ratings:

  • Min Temperature: - 65°C
  • Max Temperature: 200°C
  • Voltage: 600 Volts

55A0812 Raychem Spec 55 is classified as dual-wall airframe wire and directly crosses with M22759/43 Mil-Spec Wire.