The 55A0811 Tyco Raychem Spec 55 wire is a highly durable wire designed to be used in aircraft applications where weight, dimensional tolerance, and durability are a concern. This wire is constructed of tinned copper conductors, cross-linked ETFE insulation, an XL-ETFE jacket, and a treated aromatic polyamide braid shield. This wire is lightweight and has high resistance to chemicals and radiation. It also has a maximum temperature of +150°C and a voltage rating of 600V.

15 items

Approx LBS/MFT2.3
AWG Size24
Cond. MaterialTin-Coated Copper
Conductor Stranding19/36
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
Approx LBS/MFT3.2
AWG Size22
Cond. MaterialTin-Coated Copper
Conductor Stranding19/34
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT4.7
AWG Size20
Cond. MaterialTin-Coated Copper
Conductor Stranding19/32
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote per FT 
Approx LBS/MFT7.2
AWG Size18
Cond. MaterialTin-Coated Copper
Conductor Stranding19/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
Approx LBS/MFT9
AWG Size16
Cond. MaterialTin-Coated Copper
Conductor Stranding19/29
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
Approx LBS/MFT13.8
AWG Size14
Cond. MaterialTin-Coated Copper
Conductor Stranding19/27
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
Approx LBS/MFT20.5
AWG Size12
Cond. MaterialTin-Coated Copper
Conductor Stranding37/28
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
Approx LBS/MFT32.4
AWG Size10
Cond. MaterialTin-Coated Copper
Conductor Stranding37/26
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 

55A0811 Tyco Raychem Spec 55 (M22759/34) Specifications

55A0811 Spec 55 Construction:

  • Conductor: Tin-coated copper
  • Insulation: Radiation-crosslinked, modified ETFE
  • Wall Thickness: 0.254 mm (0.010 in.)
  • Wall Construction: Dual-Wall

55A0811 Spec 55 Ratings:

  • Min Temperature: - 65°C
  • Max Temperature: 150°C
  • Voltage: 600 Volts

55A0811 Raychem Spec 55 is classified as dual-wall airframe wire and directly crosses with M22759/34 Mil-Spec Wire.