Home
loading content

55A0811 - M22759/34

The 55A0811 Tyco Raychem Spec 55 wire is a highly durable wire designed to be used in aircraft applications where weight, dimensional tolerance, and durability are a concern. This wire is constructed of tinned copper conductors, cross-linked ETFE insulation, an XL-ETFE jacket, and a treated aromatic polyamide braid shield. This wire is lightweight and has high resistance to chemicals and radiation. It also has a maximum temperature of +150°C and a voltage rating of 600V.

15 items

55a0811-8
Approx LBS/MFT60.3
AWG Size8
Cond. MaterialTin-Coated Copper
Conductor Stranding133/29
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
55a0811-6
Approx LBS/MFT94.5
AWG Size6
Cond. MaterialTin-Coated Copper
Conductor Stranding133/27
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
55a0811-4
Approx LBS/MFT150
AWG Size4
Cond. MaterialTin-Coated Copper
Conductor Stranding133/25
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
55a0811-2
Approx LBS/MFT239
AWG Size2
Cond. MaterialTin-Coated Copper
Conductor Stranding665/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
55a0811-1
Approx LBS/MFT290
AWG Size1
Cond. MaterialTin-Coated Copper
Conductor Stranding817/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
55a0811-0
Approx LBS/MFT377
AWG Size0, 1/0
Cond. MaterialTin-Coated Copper
Conductor Stranding1045/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 
55a0811-00
Approx LBS/MFT487
AWG Size00, 2/0
Cond. MaterialTin-Coated Copper
Conductor Stranding1330/30
Insul. MaterialCross-Linked Ethylene Tetrafluoroethylene (XL-ETFE)
Max. Temp150C
Mil-SpecM22759/34
Min. Temp-65C
Requires Quote 

55A0811 Tyco Raychem Spec 55 (M22759/34) Specifications

55A0811 Spec 55 Construction:

  • Conductor: Tin-coated copper
  • Insulation: Radiation-crosslinked, modified ETFE
  • Wall Thickness: 0.254 mm (0.010 in.)
  • Wall Construction: Dual-Wall

55A0811 Spec 55 Ratings:

  • Min Temperature: - 65°C
  • Max Temperature: 150°C
  • Voltage: 600 Volts

55A0811 Raychem Spec 55 is classified as dual-wall airframe wire and directly crosses with M22759/34 Mil-Spec Wire.