FR-EPR/CPE Instrumentation Cable with Individual and Overall Shielded Pairs

Part Number AWG SizeConductor StrandingNom. O.D. of Cable (in)No. of PairsNom. Insul. Thick. (in)Approx LBS/MFTJacket Thick
139850-18 18 7/.0152 .473 2 .025 83 .045
139855-18 18 7/.0152 .586 4 .025 152 .060
139860-18 18 7/.0152 .751 8 .025 259 .060
139865-18 18 7/.0152 .948 12 .025 398 .080
139870-18 18 7/.0152 1.050 16 .025 502 .080
159635-18 18 7/.0152 1.185 20 .025 623 .080
139875-18 18 7/.0152 1.220 24 .025 709 .080
168620-18 18 7/.0152 1.474 36 .025 1008 .080
168625-18 18 7/.0152 1.780 50 .025 1454 .110
140250-18 16 7/.0192 .500 2 .025 103 .045
140260-18 16 7/.0192 .650 4 .025 189 .060
140265-18 16 7/.0192 .755 6 .025 268 .060
140270-18 16 7/.0192 .840 8 .025 330 .060
139880-18 16 7/.0192 1.065 12 .025 506 .080
140495-18 16 7/.0192 1.185 16 .025 643 .080
168630-18 16 7/.0192 1.320 20 .025 777 .080
139885-18 16 7/.0192 1.485 24 .025 932 .080
144130-18 16 7/.0192 1.760 36 .025 1410 .080
144125-18 16 7/.0192 2.035 50 .025 1883 .110

FR-EPR/CPE Instrumentation Cable with Individual and Overall Shielded Pairs
UL Type TC, 600 V

Product Approvals:

  • Industry Compliances:
    • UL 1277 Type TC
    • UL 1581
    • ICEA S-82-552
  • Flame Tests Compliances:
    • UL 1581 VW-1
    • UL 1277
    • IEEE 383
    • IEEE 1202
    • CSA FT-4
    • ICEA T-29-520
  • Other Compliances:
    • EPA 40 CFR, Part 261 for leachable lead content per TCLP
    • OSHA acceptable

FR-EPR/CPE Instrumentation Cable with Individual and Overall Shielded Pairs Construction:

  • Conductor:
    • 18 AWG and 16 AWC tinned, annealed copper per ASTM B33
    • Class B stranding per ASTM B8
  • Insulation:
    • Flame retardant Ethylene Propylene Rubber (FR-EPR) Type II
    • Color-coded per ICEA Method 1:
      • Pairs: Black and White
  • Shield:
    • Individual pairs are 100% individually shielded with aluminum/polyester in contact with stranded tinned copper drain wire.
  • Jacket:
    • Flame retardant thermoplastic Chlorinated Polyethylene (CPE)
  • Options:
    • Bare copper conductor
    • Class C Stranding
    • Overall shielded pairs
    • Individual and Overall shielded pairs/traids
    • CCTC-Cross-Linked Polyethylene (XLPE) insulation
    • FREP® XL-flame retardant, thermoset Chlorinated Polyethylene (XL-CPE) jacket
    • FREP® II-flame retardant, thermoplastic Low-Smoke, Zero-Halogen (LSZH) Polyolefin jacket
    • FREP® 300V-UL Type PLTC
    • Other constructions available upon request

FR-EPR/CPE Instrumentation Cable with Individual and Overall Shielded Pairs Applications:

  • Typical applications include audio, intercom, control, energy management and alarm circuits.
  • Acceptable for use in free air or raceways or direct burial
  • In wet or dry locations
  • Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC

FR-EPR/CPE Instrumentation Cable with Individual and Overall Shielded Pairs Features:

  • Rated at 90°C wet or dry
  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Sunlight and weather resistant
  • Excellent electrical, thermal, and physical properties
  • Excellent moisture resistance
  • Excellent resistance to compression cuts and heat deformation
  • Excellent flame resistance-burns to an ash; does not exhibit thermoplastic drip
  • Low coefficient of friction for easy pulling
  • "Heavy duty" rating per ICEA standards
  • Excellent low temperature cold bend characteristics
  • Meets cold bend test at -40°C