VNTC - PVC/Nylon/PVC Instrumentation Cable with Overall Shielded Pairs/Triads

Part Number AWG SizeConductor StrandingNo. of PairsNo. of TriadsNom. O.D. of Cable (in)Nom. Insul. Thick. (in)Approx LBS/MFTJacket Thick
117510-18 18 7/.0152 1 .280 .020 41.00 .045
119605-18 18 7/.0152 1 .300 .020 49.00 .045
117955-18 18 7/.0152 2 .440 .020 72.00 .045
159870-18 18 7/.0152 3 .465 .020 90.00 .045
117990-18 18 7/.0152 4 .505 .020 110.00 .045
168415-18 18 7/.0152 5 .570 .020 144.00 .060
168420-18 18 7/.0152 7 .585 .020 177.00 .060
115380-18 18 7/.0152 12 .770 .020 277.00 .060
135485-18 18 7/.0152 16 .825 .020 355.00 .080
168425-18 18 7/.0152 20 .905 .020 455.00 .080
115375-18 18 7/.0152 24 1.020 .020 544.00 .080
115400-18 18 7/.0152 36 1.150 .020 763.00 .080
168430-18 18 7/.0152 50 1.405 .020 1036.00 .080
115415-18 16 7/.0192 1 .300 .020 52.00 .045
115420-18 16 7/.0192 1 .315 .020 61.00 .045
119205-18 16 7/.0192 2 .470 .020 93.00 .045
119600-18 16 7/.0192 3 .505 .020 117.00 .045
115395-18 16 7/.0192 4 .575 .020 160.00 .060
168435-18 16 7/.0192 5 .610 .020 190.00 .060
168440-18 16 7/.0192 7 .630 .020 239.00 .060
122295-18 16 7/.0192 12 .825 .020 370.00 .060
122305-18 16 7/.0192 16 .970 .020 513.00 .080
168445-18 16 7/.0192 20 1.010 .020 628.00 .080
115390-18 16 7/.0192 24 1.135 .020 740.00 .080
115410-18 16 7/.0192 36 1.375 .020 1063.00 .080
115405-18 16 7/.0192 50 1.570 .020 0.00 .080
118745-18 14 7/.0242 1 .325 .015 62.00 .045

VNTC - PVC/Nylon/PVC Instrumentation Cable with Overall Shielded Pairs/Triads
UL Type TC, 600 V

VNTC - PVC/Nylon/PVC Instrumentation Cable Product Approvals:

  • Industry Compliances:
    • UL 1277 Type TC
    • UL 1581
    • NEC Type TFN conductors
  • Flame Tests Compliances:
    • UL 1277
    • IEEE 383
    • IEEE 1202
    • CSA FT-4
  • Other Compliances:
    • EPA 40 CFR, Part 261 for leachable lead content per TCLP
    • OSHA acceptable

VNTC - PVC/Nylon/PVC Instrumentation Cable Construction:

  • Conductor:
    • 18 AWG and 16 AWC bare, annealed copper per ASTM B3
    • Class B stranding per ASTM B8
  • Insulation:
    • Flame retardant Polyvinylchloride (PVC) with clear Polyamide
    • Color-coded per ICEA Method 1:
      • Pairs: Black and White
      • Triads: Black, White, and Red
  • Shield:
    • Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire
  • Jacket:
    • Flame retardant, moisture- and sunlight- resistant Polyvinylchloride (PVC)
  • Options:
    • Tinned copper conductor
    • Class C Stranding
    • Individual and overall shielded pairs/triads
    • Other constructions available upon request

VNTC - PVC/Nylon/PVC Instrumentation Cable Applications:

  • In free air, raceways or direct burial
  • In wet or dry locations
  • Permitted for use in Class I Division 2 Industrial hazardous locations per NEC

VNTC - PVC/Nylon/PVC Instrumentation Cable Features:

  • Rated at 90°C dry, 75°C wet
  • Ripcord applied to all cables with jacket thickness of 60 mils or less
  • Provides sunlight, cold bend, and cold impact resistant
  • Provides excellent oil and chemical resistance
  • Offer the smallest cable O.D. available for suitable applications
  • Provides a long service life
  • Meets cold bend test at -25°C