Belden's high-temperature EPDM Hook-Up Wires carry specific temperature approvals depending on whether a UL or CSA standard is needed. The UL standard is not rated for flexing, which allows it to carry a higher temperature rating of +150°C. The CSA flexing standard has a temperature rating of +125°C. These hook-up wires have approval for use in Class 130(B), 155(F), and some 180(H) systems. Compared to Hypalon, the EPDM in these hook-up wires offers better resistance to abrasion. 

21 items

  • Belden Cable
    37101
    $0.00 / 1000 FT
    • Approx LBS/MFT: 376
    • AWG Size: 1
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • Belden Cable
    37190
    $0.00 / 1000 FT
    • Approx LBS/MFT: 447
    • AWG Size: 1/0
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • Belden Cable
    37100
    $0.00 / 1000 FT
    • Approx LBS/MFT: 559
    • AWG Size: 2/0
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • 37130
    $0.00 / 1000 FT
    • Approx LBS/MFT: 692
    • AWG Size: 3/0
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • Belden Cable
    37140
    $0.00 / 1000 FT
    • Approx LBS/MFT: 898
    • AWG Size: 4/0
    • Cond. Material: Tinned Copper
    Order
    Add to List

Belden 600V, 150°C EPDM Hook-Up Wire Specifications

EPDM Hook-Up Wire Ratings and Approvals:

  • Voltage Rating: 600V
  • CSA Approval: CSA Type CL1254 (125°C)
  • Temperature Rating: 125°C Flex/150°C No Flex

EPDM Hook-Up Wire Construction:

  • Conductor: Stranded Tinned Copper
  • Insulation: Cross-linked Ethylene-Propylene Diene Elastomer (EPDM)