add to cart success
This product has variants and can only be added to the cart by viewing the product details page.
add to cart success
Submit Request Quote
 * Denotes Required Field.
Name:
 *
Company Name:
Phone:
Email:
 *
Message:
Request Quote
 

RHH / RHW Wire (USE-2 Solar Wire)

USE-2 Solar Wire

USE-2 Solar Wire - 10 AWG

Part Number AWG SizeConductor StrandingNom. Insul. Thick. (in)Nom. O.D. (in)Approx LBS/MFTAmpacity @ 90°C
RHH/RHW 14 14 7 0.045 0.2000 43.00 30
RHH/RHW 12 12 7 0.045 0.2000 31.00 20
USE-2 10 10 7 0.045 0.2070 46.00 30
RHH/RHW 8 8 7 0.060 0.2800 73.00 55
RHH/RHW 6 6 7 0.060 0.3200 103.00 75
RHH/RHW 4 4 7 0.060 0.3700 156.00 96
RHH/RHW 2 2 7 0.060 0.4300 238.00 130
RHH/RHW 1 1 19 0.060 0.5100 308.00 150
RHH/RHW 1/0 1/0 19 0.080 0.5500 380.00 170
RHH/RHW 2/0 2/0 19 0.080 0.5900 471.00 195
RHH/RHW 3/0 3/0 19 0.080 0.6500 585.00 225
RHH/RHW 4/0 4/0 19 0.080 0.7000 727.00 260
RHH/RHW 250 250 37 0.095 0.7800 878.00 290
RHH/RHW 300 300 37 0.095 0.8300 1040.00 320
RHH/RHW 350 350 37 0.095 0.8800 1208.00 350
RHH/RHW 400 400 37 0.095 0.9300 1369.00 380
RHH/RHW 500 500 37 0.095 1.0100 1691.00 430
RHH/RHW 600 600 61 0.095 1.1200 2027.00 475
RHH/RHW 750 750 61 0.110 1.2300 2511.00 535

RHH Wire, RHW Wire
Type USE-2 Solar Wire or RHH or RHW-2 Lead Wire
UL 44, NEMA WC 70

RoHS Hook-up Wire RoHS Compliant

RHH Wire and RHW Wire / USE-2 Construction:

  • Conductor: Bare Copper
  • Insulation: Cross-linked Polyethylene (XLPE)

RHH Wire and RHW Wire / USE-2 Solar Wire Applications:

  • Cross-Link Type RHH Wire/RHW Wire can be used in aerial, raceway or direct burial allocations. USE-2 Solar Wire is commonly used as solar power cable in green energy applications. The cross-linked insulation is a general purpose, chemically cross linked polyethylene compound combining the best properties of rubber and polyethylene to provide a thermosetting material with excellent thermal, electrical and physical properties.

RHH Wire and RHW Wire / USE-2 Solar Wire Standards and Specifications:

  • RHH Wire & RHW Wire meets U.L. 44 standard for rubber covered wire, as well as standard 854 for service entrance cable. The construction and components of Type RHH Wire & RHW Wire conform to Federal Govt. Specification J-C-30A. The solid copper conductors are made to ASTM-B-3 and the standard conductors to ASTM-B-3 and -6.

Customization Services for RHH/RHW / USE-2 include:  

LSC5FS-4

LSC5FS-4 Construction:

  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Tape: Foam Polypropylene (PE) 25% Overlap
  • Drain: 24 AWG Stranded Tinned Copper 
  • Tape: Flame Retardant Tape 25% Overlap
  • Tape: Fiberglass Tape 25% Overlap
  • Tape: Marker Tape 

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5OS-4

LSC5OS-4 Construction:

  • Category 5 Defense-Link™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Tape: Polypropylene (PE) 25% Overlap
  • Shield: Aluminum/Polyester
  • Braid: 36 AWG Tinned Copper

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5OS-4

LSC5OSW-4 Construction:

  • Category 5e Shielded Defense-Link™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to varying lays
  • Cable Assembly: 4 Pairs Cabled with Separator
  • Gel: Cable Filled with Water Blocking
  • Both Tapes: Water Blocking Tape
  • Braid: 36 AWG Tinned Copper

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2015-226

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown

LSC5POS-4 Compose Construction:

LSC5POS-4

  • Category 5e Shielded Defense-Link ™ Shipboard Cable
  • Pair Assembly: Conductors Twisted to Varying Lays
  • Cable Assembly: 4 Pairs Cabled With Separator
  • 36 AWG Tinned Copper Braid
  • Tape: Polypropylene 25% Overlap

Compliances:

  • Acid Gas Generation: MIL-DTL M24643C (4.8.23)
  • Halogen Content: MIL-DTL M24643C (4.8.23)
  • NES 713 Toxicity: MIL-DTL M24643C (4.8.27)
  • Flame Propagation: MIL-DTL M24643C (4.8.13)
  • Jacket Immersions: MIL-DTL M24643C (4.8.26)
  • Jacket Tear: MIL-DTL M24643C (4.8.20)
  • Heat Distortion: MIL-DTL M24643C (4.8.15)
  • Weathering: MIL-DTL M24643C (4.8.28)
  • QPL Approved: Ser. 05S/2017-354

Electrical Performance:

  • Voltage Rating: 300 Volts
  • Max. DC Resistance: 9.83Ω/100m
  • Max DC Resistance Unbalance: 5.0 %
  • Nominal Velocity of Propagation: 68 %
  • Max Propagation Delay Skew: 45 ns/100m

 

Category 5e Electricals Chart (Per ANSI/TIA 568-C.2)

 

Freq. Return Loss (dB) Attenuation (dB/100m) NEXT (dB/100m) PSNEXT (dB/100m) ACRF (dB/100m) PSACRF (dB/100m)
(MHz.) (Min) (Max) (Min) (Min) (Min) (Min)
1 20 2 65.3 62.3 63.8 60.8
4 23 4.1 56.3 53.3 51.7 48.7
8 24.5 5.8 51.8 48.8 45.7 42.7
10 25 6.5 50.3 47.3 43.8 40.8
16 25 8.2 47.3 44.3 39.7 36.7
20 25 9.3 45.8 42.8 37.7 34.7
25 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17 38.4 35.4 27.8 24.8
100 20.1 22 35.3 32.3 23.8 20.8

 

Category Color Code:

 

Color Code
Pair 1 Blue - White/Blue
Pair 2 Orange - White/Orange
Pair 3 Green - White/Green
Pair 4 Brown - White/Brown